Intelligent Dose and Dose Rate Measuring System


Intelligent Monitoring System to measure and display dose and dose rate for medical and general applications with computer assisted analysis of acquired data.Suitable for patient-monitoring in nuclear medical radio-iodine-therapy, for room- and process- monitoring of laboratories and nuclear power plants as well as general monitoring at manufacturing radio nuclides.Several bus-compatible components (up to 255) can be arranged in a custom-designed and universal monitoring system. The analysis software bases on a modern client-server-concept and allows a fast incorporation of special customer demands in terms of analysis and presentation of acquired     data.

Download
DLMon RMon Prospekt DE 04-2014(1).pdf
Adobe Acrobat Dokument 305.0 KB
Download
step_dlmon_skb_dlmon_software_kurzbeschr
Adobe Acrobat Dokument 1.1 MB
Download
step_dlmon_sb_softwarebeschreibung_dlmon
Adobe Acrobat Dokument 4.6 MB


Components

Intelligent, bus-compatible Detector with an internal micro-controller

Intelligent, bus-compatible Single and Double Displays with an internal micro-controller and selectable threshold, incl. alarm

Intelligent, bus-compatible Large-Scale Displays with special functions

Central data acquisition and processing unit (consisting of PC, printer, no-break power supply and RS-485 interface)

Client-Server-Software (operating systems: Windows NT, 2000, XP)

Data storage in a MS-SQL data base


Component: Intelligent Radiation Detector SON 16

  • Measured value: Photon dose rate equivalent respectively, Ambient dose rate equivalent
  • Detector: Geiger-Mueller-Tube / Type 70004
  • Measurement range: 0.1 µSv/h* … 500 µSv/h *(Measuring period 200 s, measuring uncertainity < 3 %)
  • Energy range: 35 keV … 1,3 MeV
  • Collimator: Material: lead (Pb), Aperture angle: ± 30°

Electronics

  • Micro-controller with internal memory
  • 128-kByte-FLASH-EEPROM
  • Data transfer via an RS-485 interface
  • Calculation of dose rate from counting rate
  • Correction of detector dead time and background counting rate
  • Data memory (up to 9088 values) including date and time in non-volatile cycling memory, even at a shutdown of the PC
  • Acquisition parameters (cquisition time, number of cycles) can be defined
  • Continuous self-monitoring of all internal and external operating voltages, functional tests of the detector, of the interface and memory

Component: Intelligent Radiation Detector SON 20

  • Measured value: Photon dose rate equivalent respectively, Ambient dose rate equivalent
  • Detector: Geiger-Mueller-Tube / Type 70013E (energy compensated for the photon equivalent dose rate), Geiger-Mueller-Tube / Type 70013A (energy compensated for the ambient equivalent dose rate)
  • Measurement range: 0.05 µSv/h* … 200 µSv/h *(Measuring period 200 s, measuring uncertainity < 3 %)
  • Energy range: 35 keV … 1,3 MeV
  • Collimator: None

Electronics

  • Micro-controller with internal memory
  • 128-kByte-FLASH-EEPROM
  • Data transfer via an RS-485 interface
  • Calculation of dose rate from counting rate
  • Correction of detector dead time and background counting rate
  • Data memory (up to 9088 values) including date and time in non-volatile cycling memory, even at a shutdown of the PC
  • Acquisition parameters (cquisition time, number of cycles) can be defined
  • Continuous self-monitoring of all internal and external operating voltages, functional tests of the detector, of the interface and memory

Optional extras

  • Lead collimator
  • Potential free display for alarming threshold overruns and disturbances, every output can withstand 24 volt and 0.5 amps

Component: Intelligent Display AT1-x

 

Intelligent single and double displays (AT1-1 and AT1-2) for visual presentation of measurements in flush-mounted construction

 

Visualization of measurements

  • 3½-digit-display (height of the digits: 17.8 mm), LCD with backlight
  • Visual and acoustical alarm at the display (to switch off by software)
  • Quasi-analogue bar graph (20 elements)
  • 3 LED's (red, yellow, green) for immediately signalling of the health risk for the staff
  • (separate programmable thresholds for every display)
  • Data transfer by an RS-485 interface
  • Storage of all relevant parameters in an EEPROM

 

Electronics

  • Microcontroller with an internal memory
  • 128-kByte-FLASH-EEPROM
  • Data transfer by an RS-485 interface
  • 3 internal thresholds
  • Data Memory in a non-volatile, cyclic memory, even at a computer breakdown
  • Self-monitoring of all internal and external operation voltages and the interface

    Optional extras
  • Construction frame for on-wall installation

Component: Module-Server

Local server for data-acquisition from connected radiation detectors and data transmission to corresponding display units

Other features
  • Automatic monitoring of all bus components
  • Fault-tolerant data acquisition
  • Automatic data backup (daily, monthly) in a MS-SQL-database
  • Calibrate function for detectors
  • Providing data for various client-Software

Component: DLMon client software 
Analysis software for patient monitoring for use in radio-iodine-therapy

Features

  • Display of the arrangement of each detector in the rooms to be monitored
  • Detector overview: display of the current dose rate digitally as well as by a colour code
  • Display of patient-dose-rate diagram
  • Long-term archiving of acquired data
  • Detector calibration
  • Marginal check: if pre-selected thresholds are exceeded - emission of warning signals and/or activation of safety facilities
  • Patient-database with function for the patient check-in (optional: chip-card reader)
  • Patien-diagrams including the display of discharge-thresholds (freely selectable)
  • Data fit to estimate the effective half-life of the incorporated nuclide
  • Diverse data-analysis-functions (e.g. uptake-calculation, calculation of the hearth dose)
  • Transfer of patients by mouse click
  • Drawing up reports on chosen periods
  • Printing forms for patient data, patient dose rate history, ward occupancy
  • Tool for patient planning

Downloads DLmon:

Component: RMon client software

Analysis software for room- and process-monitoring in laboratories and radioactive contaminated rooms. The analysis software includes following functions:

Features

  • Display of the arrangement of each detector in the rooms to be monitored
  • Detector overview: display of the current dose rate digitally as well as by a colour code
  • Display of patient-dose-rate diagrams
  • Detector calibration
  • Marginal check: if pre-selected thresholds are exceeded - emission of warning signals and/or activation of safety facilities
  • Long-term archiving of acquired data
  • Printing forms for patient dose rate history


 

Referencelist: Radiation monitoring system DLMon

 

 2017

  • Installation of DLMon-System in the new building of the University Hospital Jena
  • Renewel of the DLMon-System in the KABEG Klinkikum Klagenfurt
  • Partial Renewel of the DLMon-System in the University Hospital Halle

2016

  • Partial Renewel of the DLMon-System in the Central Clinic Bad Berka
  • Installation of DLMon-System in the Nuclear Medicine Department in the clinic Sozialstiftung Bamberg

2015

  • Expansion of the DLMon-System in the University Hospital Leipzig

2014

  • Partial Renewel of the DLMon-System in the Landeskrankenhaus Innsbruck/TirolKliniken
  • Installation of DLMon-System in the American Hospital Dubai

2013

  • Installation of DLMon-System in the Prince Sultan Medical Military City in Riyadh City, Saudi Arabien

2012

  • Partial Renewel of the DLMon-System in the Clinic Chemnitz

2010

  • Installation of DLMon-System in the Saint Bartholomew's Hospital in London

2009

  • Installation of DLMon-System in the University Hospital Jena

2008

  • Fitting of two clinics with room monitoring system in South Korea in cooperation with GnG Radcom, Co. Ltd.

2007

  • Installation of DLMon-System in the Clinic for Nuclear Medicine in the University Hospital at the Johann-Wolfgang-Goethe-University Frankfurt am Main.
  • Installation of DLMon-System in the service center for Radiology / Nuclear Medicine in the Sana Clinic Hof GmbH

2005

  • Installation of DLMon-System in the Clinic for Diagnostische Radiologie and Nuclear Medicine in the University Hospital at the Otto-von-Guericke-Universität Magdeburg
  • Installation of DLMon-System in the Clinik for Nuclear Medicine in the Clinic Kemperhof Koblenz
  • Installation of DLMon-System in the Nuclear Medicine Department of Dubai Hospital / Dubai (VAE)
  • Installation of DLMon-System in the KABEG Clinic Klagenfurt

2002

  • Installation of DLMon-System in the Clinic and Polyclinic for Nuclear Medicine in the Universitätsklinikum Leipzig AöR
  • Neubau and Expansion of the DLMon-System in the Clinic for Nuclear Medicine / PET-Zentrum in the Zentralklinik Bad Berka GmbH

2001

  • Installation of DLMon-System in the Clinic for Nuclear Medicine at the Klinikum Chemnitz gGmbH
  • Installation of DLMon-System in the Radiologie and Nuclear Medicine Department in the Robert-Bosch-Hospital Stuttgart
  • Installation of DLMon-System in the clinic for Nuclear Medicine in the Landeskrankenhaus-Universitätskliniken Innsbruck (Austria)

1999

  • Installation of DLMon-System in the clinic and Polyclinic for Nuclear Medicine in the University Hospital at the Martin-Luther-University Halle-Wittenberg

1997

  • Installation of DLMon-System in the clinic for Nuclear Medicine at the HELIOS Clinic Erfurt